Unique Design High Torque AC Permanent Magnet Synchronous Motor

Unique Design High Torque AC Permanent Magnet Synchronous Motor

Special Design Higher Torque AC Everlasting Magnet Synchronous Motor

Solution Function
one.Ideal for the 2500rpm rated velocity
2.Substantial energy & higher torque
three.High performance
four.Small measurement
5.Minimal noise reduced vibration
six.Patented cooling construction
7.Effortless servicing and extended existence time
8.Resilient, trustworthy

Technical specs
Model type: SRPM155L85
Voltage: 380V AC
Rated Energy: 5KW
Greatest Energy:9KW(30s)
Charge Torque : 19N.m
Highest Torque:34N.m
Rated Velocity: 2500rpm
Optimum Speed:4000rpm
Rated Existing:10A
Isolation: H
Drinking water/Dust Evidence: IP54(IP67 choice)
N Bodyweight: about 15KG
Cooling Approach: organic cooling
Installation Strategy: MB35

Software
Higher-velocity Compressors,Enthusiasts,Pumps

Other motors you will be fascinated in

Motor variety Voltage
(V AC)
Rated electricity
(kW)
Rated torque (N.m) Rated pace
(rpm)
Effectiveness
(%)
Service Factor Insulation Ingress protection Pole Amount Excess weight
(kg)
Cooling Technique Position Sign Installation Method
SRPM151M8XW11 380 eleven eleven 9600 96 S1 H/F IP67 eight ten Oil circulation Resolver B35
SRPM205M8XO45 380 forty five 36 12000 ninety six.3 S1 H/F IP67 eight 35 Oil circulation Resolver B35
SRPM205M8XO55 380 55 forty three.eight 12000 96.3 S1 H/F IP67 8 38 Oil circulation Resolver B35
SRPM205M8XO75 380 seventy five 59.seven 12000 ninety six.5 S1 H/F IP67 eight 43 Oil circulation Resolver B35
SRPM205M8XO90 380 90 seventy one.six 12000 96.5 S1 H/F IP67 eight forty seven Oil circulation Resolver B35
SRPM205M8XO110 380 a hundred and ten 87.six 12000 96.five S1 H/F IP67 8 75 Oil circulation Resolver B35
SRPM205M8XO132 380 132 105 12000 ninety six.five S1 H/F IP67 8 80 Oil circulation Resolver B35
SRPM205M8XO160 380 a hundred and sixty 127.three 12000 96.five S1 H/F IP67 8 87 Oil circulation Resolver B35
SRPM205M8XO185 380 185 147.2 12000 ninety six.5 S1 H/F IP67 eight ninety five Oil circulation Resolver B35

FAQ
1. Can performanent magnet synchronous motor be utilised as generator? 

No. Everlasting magnet synchronous motor is completely various from generator. It is only ac motor that outputs velocity and torque to push electric products, but not energy provide. 
 
2. Why can not right use three section ac source voltage to start everlasting magnet synchronous motor? 
Becuase rotor is with massive innertia, and magetic information spins so rapidly that static rotor has no way to spin with magetic submitted. 
 
three. Any special technical request on this motor’s VFD driver? And Do you have this sort of driver? 
Long term magnet synchronous motor’s driver should be vector control VFD with unique interior software program, these kinds of as Siemens 6SE70 collection, Yakawa CR5 collection, ABB ACS800 series, Mitsubishi A740 collection, B&R P84 and P74 collection, and so forth.. Yes, our MH300 collection VFD matches with this motor. 
 
4. Is there any protecting actions to defend long term magnet rotor from failure? 
Of course, each long lasting magnet rotor passes corrossion resistance, consistency, high temperature demagnetization take a look at, linear demagnetization check, and so forth. Its demagnetization index is in two%. But if doing work environment is serious oxiditive corrosion, kindly suggest for greater defense degree. 
 
5. In which is this long lasting magnet synchronous motor typically employed to? 
This long lasting magnet synchronous motor is normally utilised to variable frequency speed circumstance.

 

Unique Design High Torque AC Permanent Magnet Synchronous Motor

Tags