Adjusted Speed Permannet Magnetic Axial Fan ECI Motor

Adjusted Speed Permannet Magnetic Axial Fan ECI Motor

Altered pace Permannet Magnetic Axial fan ECI Motor

Solution Transient
E-MAX motor is the special made everlasting magnet synchronous motor based mostly on the IEC norm. E-MAX PMSM will be employed for next generation which need to have more power conserving item. Exceed IE4 variable velocity AC motor (IEC60034-30-2-2016).

E-MAX motor is the very first generation of DBS EC motor. E-MAX has led to produce the following technology of technologies in motor effectiveness and performance.
E-MAX motor have two sequence:
E-Max commercial
IEC Frame 71 to ninety long term magnet synchronous motor integrated travel
E-Max CZPT
IEC Body seventy one to 132 everlasting magnet synchronous motor

E-Max Commercial collection (ECI sequence)

Model Body Rated Output Output Highest
measurement torque @1500rpm @3000rpm pace
  (Nm)** (kW) (kW) (rpm)
T71ECI01X36 seventy one 1.2 .2 .forty one 3600
T71ECI02X36 2.four .forty one .82 3000
T71ECI03X18 three.two .fifty five 1800
T90ECI03X36 90 three.2 .55 one.one 3600
T90ECI05X30 four.eight .seventy five one.5 3000
T90ECI07X18 seven 1.one 1800

** The rated torque is dependent on the motor cooling technique. The detail torque you should see knowledge sheet.
E-Max Business Motor Push Operate
CW/CCW chooseCZPTt-cease terminal0-10VDC velocity controlRS485 ModbusSpeed hand management by adjustable resistanceSpeed comments

E-Max CZPT sequence (EC collection)

Model Body Rated Output Output Optimum
dimensions torque @15000rpm @3000rpm speed
  (Nm)** (kW) (kW) (rpm)
T71EC01X36 seventy one 1.two .two .41 3600
T71EC02X36 2.four .forty one .eighty two 3600
T71EC03X36 three.2 .55 one.1 3000
T90EC03X36 ninety three.2 .fifty five 1.one 3600
T90EC05X36 4.8 .75 1.5 3600
T90EC07X36 seven one.one 2.2 3600
T100EC10X36 100 9.five 1.five three 3600
T100EC14X36 fourteen 2.2 4 3600
T100EC19X30 19.1 three five.five 3000
T132EC26X30 132 twenty five.5 four seven.5 3000
T132EC35X30 35 5.five 11 3000
T132EC48X30 47.seven seven.five 15 3000
T132EC59X30 fifty eight.nine nine.two 18.5 3000
T132EC70X30 70 eleven 22 3000

** The rated torque is based on the motor cooling strategy. The depth torque you should see data sheet.

Performance course
E-MAX motor has ultra-higher effectiveness both at entire load and gentle load. The flat performance curve can preserve far more power when the motor push the supporter or pump in HVAC discipline.
Assess to IE4 motor effectiveness course E-MAX

E-Max Industrial sequence

** Method performance incorporate the motor and generate efficiency.

E-Max CZPT collection

** Effectiveness is only motor efficiency.

Product number nomenclature
T  90  EC  03  V  36  C2  B14  P  T1
1   2   3    4  5   6   7    8    9  10
 

Placement Character Description
1 “T” Product platform
two “ninety” Frame dimensions: IEC ninety#
3 “EC” EC: long lasting magnet motor
ECI: long lasting magnet motor with built-in drvie
4 “03” Rated torque
5 “V” Cooling technique:
G = CZPT functions, with admirer and enthusiast hood. IC411
V = Air flow purposes, CZPT fan and fan hood.
6 “36” Greatest pace: 3600 rpm
seven C2 Power line connection approach:
T1 = Terminal box on top
T2 = Terminal box on NDE
C1 = No terminal box, electrical power line from housing
C2 = No terminal box, power line from NDE
eight B14 Mounting technique:
B3, B14, B5, B34, B35
nine P P = Slid rail
10 T1 Voltage code:
T1: 3 stage 360-440 V
T2: three period two hundred-240 V
S1: one section two hundred-240 V
S2: 1 phase one hundred fifteen V

VFD thing to consider
PMSM should drive by the VSD. The motor can not hook up to the standard AC electricity directly. The VSD can be the commercial generate with vector manage or PM motor control manner. VSD want to be established up the appropriate motor parameter (see beneath table). The depth parameters can be uncover in the design data sheet.

Power pick consideration
       The power and torque in previously mentioned model list is the rated electrical power or torque when the motor has not any cooling approach (IC410). If the motor cooled by the wheel or the load the motor power can be greater. The detail running selection remember to see element design info sheet. Underneath chart is a sample to make a decision the electrical power at diverse cooling problem.

Engineering

  1. Knowledgeable on the fan, pump, compressor and motion software with long lasting magnet motor style
  2. Motor model building and simulation, functionality calculation, sounds optimization
  3. Motor content databases: silicon metal, magnet, copper, aluminum
  4. Substantial precision check tools and instrument

              

Producing and quality control

  1. Automated winding device to get much better consistency
  2. CZPTal check equipment
  3. Magnetic flux examining

CZPTer Software

CZPTers & Exhibitions

  

Adjusted Speed Permannet Magnetic Axial Fan ECI Motor

Tags